Depth-dose measurement corrections for the surface electronic brachytherapy beams of an Esteya® unit: a Monte Carlo study

2020

Abstract Three different correction factors for measurements with the parallel-plate ionization chamber PTW T34013 on the Esteya electronic brachytherapy unit have been investigated. This chamber type is recommended by AAPM TG-253 for depth-dose measurements in the 69.5 kV x-ray beam generated by the Esteya unit. Monte Carlo simulations using the PENELOPE-2018 system were performed to determine the absorbed dose deposited in water and in the chamber sensitive volume at different depths with a Type A uncertainty smaller than 0.1%. Chamber-to-chamber differences have been explored performing measurements using three different chambers. The range of conical applicators available, from 10 to 30…

Materials scienceRadiological and Ultrasound Technologymedicine.medical_treatmentMonte Carlo methodBrachytherapyConical surface030218 nuclear medicine & medical imagingComputational physics03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisAbsorbed doseIonization chambermedicineDosimetryRadiology Nuclear Medicine and imagingDepth doseBeam (structure)Physics in Medicine & Biology
researchProduct

Design and characterization of a new high-dose-rate brachytherapy Valencia applicator for larger skin lesions

2016

Purpose: The aims of this study were (i) to design a new high-dose-rate (HDR) brachytherapy applicator for treating surface lesions with planning target volumes larger than 3 cm in diameter and up to 5 cm in size, using the microSelectron-HDR or Flexitron afterloader (Elekta Brachytherapy) with a 192Ir source; (ii) to calculate by means of the Monte Carlo(MC) method the dose distribution for the new applicator when it is placed against a water phantom; and (iii) to validate experimentally the dose distributions in water. Methods: The penelope2008MC code was used to optimize dwell positions and dwell times. Next, the dose distribution in a water phantom and the leakage dose distribution arou…

Materials sciencebusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineImaging phantomHigh-Dose Rate Brachytherapy030218 nuclear medicine & medical imagingPercentage depth dose curve03 medical and health sciencesKerma0302 clinical medicine030220 oncology & carcinogenesisIonization chambermedicineDosimetryNuclear medicinebusinessMedical Physics
researchProduct

Dosimetric characteristics of a new unit for electronic skin brachytherapy

2013

PURPOSE: Brachytherapy with radioactive high dose rate (HDR) (192)Ir source is applied to small skin cancer lesions, using surface applicators, i.e. Leipzig or Valencia type. New developments in the field of radiotherapy for skin cancer include electronic brachytherapy. This technique involves the placement of an HDR X-ray source close to the skin, therefore combining the benefits of brachytherapy with the reduced shielding requirements and targeted energy of low energy X-rays. Recently, the Esteya(®) Electronic Brachytherapy System (Esteya EBS, Elekta AB-Nucletron, Stockholm, Sweden) has been developed specifically for HDR brachytherapy treatment of surface lesions. The system provides rad…

Original Paperelectronic brachytherapybusiness.industrymedicine.medical_treatmentTreatment durationSuperficial radiotherapyBrachytherapyElectronic skinsuperficial radiotherapyRadiation therapyLow energyOncologynonmelanoma skin-cancermedicineskin brachytherapyRadiology Nuclear Medicine and imagingNuclear medicinebusinessDose rateDepth doseJournal of Contemporary Brachytherapy
researchProduct

A Monte Carlo-based dosimetric characterization of Esteya® , an electronic surface brachytherapy unit

2018

PURPOSE The purpose of this work is threefold: First, to obtain the phase space of an electronic brachytherapy (eBT) system designed for surface skin treatments. Second, to explore the use of some efficiency enhancing (EFEN) strategies in the determination of the phase space. Third, to use the phase space previously obtained to perform a dosimetric characterization of the Esteya eBT system. METHODS The Monte Carlo study of the 69.5 kVp x-ray beam of the Esteya® unit (Elekta Brachytherapy, Veenendaal, The Netherlands) was performed with PENELOPE2014. The EFEN strategies included the use of variance reduction techniques and mixed Class II simulations, where transport parameters were fine-tune…

PhysicsMonte Carlo methodDose profileGeneral MedicinePhoton energy030218 nuclear medicine & medical imagingPercentage depth dose curveComputational physics03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisAbsorbed doseDosimetryVariance reductionEnergy sourceMedical Physics